Salta al contenuto

Via Campegna 135, 80124-Napoli

La nostra Location

+39 081 5936511 - 081 5934226

Chiamaci, siamo sempre disponibili

  • Home
  • Chi siamo
  • CATALOGO
    • ANTINTRUSIONE
    • ANTINCENDIO e Rilev. GAS
    • AUTOMAZIONE / DOMOTICA
    • CAVI E ACCESSORI
    • CONTROLLO ACCESSI
    • NETWORKING
    • SICUREZZA HOME WIRELESS
    • VIDEOSORVEGLIANZA
  • Contatti
  • Area Riservata
    • UTC INTRUSIONE
    • UTC RILEVAZIONE INCENDIO
    • UTC SOFTWARE
    • UTC TVCC
    • gli altri Files…
      • CARDIN-MITECH-SAFIRE
      • BORINATO-VENITEM-UNIVIEW
      • DUEVI-VIMO-ELAN-CROW
      • DEFENDERTECH-UTEPO
      • VISIOTECH-CIAS-TEXECOM
  • Login
Menu
  • Home
  • Chi siamo
  • CATALOGO
    • ANTINTRUSIONE
    • ANTINCENDIO e Rilev. GAS
    • AUTOMAZIONE / DOMOTICA
    • CAVI E ACCESSORI
    • CONTROLLO ACCESSI
    • NETWORKING
    • SICUREZZA HOME WIRELESS
    • VIDEOSORVEGLIANZA
  • Contatti
  • Area Riservata
    • UTC INTRUSIONE
    • UTC RILEVAZIONE INCENDIO
    • UTC SOFTWARE
    • UTC TVCC
    • gli altri Files…
      • CARDIN-MITECH-SAFIRE
      • BORINATO-VENITEM-UNIVIEW
      • DUEVI-VIMO-ELAN-CROW
      • DEFENDERTECH-UTEPO
      • VISIOTECH-CIAS-TEXECOM
  • Login
Search
Close

S739DVT-RST1

  • PANORAMICA
  • SOLUZIONI
  • DETTAGLIO
  • SPECIFICHE

S739DVT-RST1

Videotrasmettitore digitale a canale singolo, in modulo rack, con dati up-the-coax bidirezionali, 1 fibra

– Trasmissione controllo, risposta e genlock bidirezionale e video unidirezionale su una o due fibre multimodali
– Compatibilità con tutti i principali sistemi di controllo up-the-coax
– Risoluzione 800 linee TV
– Funziona su una distanza massima di 18 km
– Design del contenitore moderno e robusto

Tipo fibra

Multi Mode (MM)

n° di fibre

1

Stand Alone

codice

S739DVT-EST1

S739DVT-RST1

S739DVR-EST1

S739DVR-RST1

Single Mode (SM)

2

Rack

S739DVT-EST2

S739DVT-RST2

S739DVR-EST2

S739DVR-RST2

Anteprima

Panoramica

Il sistema dati di controllo e video S739DV rappresenta un’importante innovazione nel campo dei collegamenti in fibra ottica per i sistemi di controllo up-the-coax. Nei sistemi di controllo “up-the-coax”, i segnali elettronici viaggiano su cavo coassiale.

Funzionalità di diagnostica superiori

La tecnologia di diagnostica SMARTS™ prevede l’utilizzo di LED di ingresso/uscita per l’intensità dei segnali video, ottici, di comando, di risposta e sync.

Ampia compatibilità del sistema

Oltre alle funzioni video e controllo, il collegamento in fibra S739DV trasmette i segnali di risposta dalla telecamera alla centrale di controllo. Il sistema S739DV può inoltre trasmettere segnali di sync genlock incorporati, se il sistema di controllo utilizza questa funzione. Il sistema S739DV funziona con sistemi up-the-coax di tutti i principali marchi.

Nel dettaglio

  • – Trasmissione controllo, risposta e genlock bidirezionale e video unidirezionale su una o due fibre multimodali
  • – Compatibilità con tutti i principali sistemi di controllo up-the-coax
  • – Risoluzione 800 linee TV
  • – Funziona su una distanza massima di 18 km
  • – Design del contenitore moderno e robusto
  • – Diagnostica SMARTS™
  • – Diagnostica SMARTS™
  • – La configurazione standalone include un trasmettitore multimodale, un ricevitore multimodale e due alimentatori

Specifiche tecniche

Video
Canali Video1
Channels1
FormatEIA,​ CCIR,​ NTSC and PAL
Input/output signal1.0 V pp composite
Bandwidth10 MHz
Video resolution800 TVL
Signal-to-noise ratio> 54 dB
Input/output impedance75 ohms
Differential phase< 3°
Differential gain< 3%
Dati
Data channels1
  • Scheda tecnica
Ottica
Tipo di fibraMulti Mode (MM)
No. di fibre1
Tipo di connettore fibraST
Generale
Ricezione/trasmissioneTrasmettitore
Fisico
Fattore di formaRack
Data
FormatsAmerican Dynamics,​ Baxall Burle,​ Elbex (sync and control),​ Panasonic (PTZ and VD2),​ Pelco,​ Robot,​ Sensormatic,​ VCS format,​ Vicon,​ Videoalarm,​ and others
 Check with control system manufacturer for distance limits.
Location in vertical intervalControl signal imposed on lines 8-19 (even fields) and lines 9-20 (odd fields)
Pulse amplitude50 mV to 2 V
Genlock Sync
Detection areaCan be imposed on all lines outside the control area
Sync amplitudeUp to 6 V
Optical
ModeMultimode
Optical budget13 dB
EmitterMultimode LED or Laser (depending on wavelength); Single Mode Laser
WavelengthMultimode 850nm and/or 1300 nm; Single Mode 1310 nm and 1550 nm
Operating distanceMultimode Up to 11 mi. (18 km); Single Mode 31 mi. (50 km)
Gain controlOptical Automatic Gain Control (OAGC)
Launch power-15 dBm minimum
Receiver sensitivity28 dBm minimum
Electrical
Input power13.5 VDC regulated
Current requirement400 mA (transmitter); 380 mA (receiver)
Power consumption5.4 W (transmitter); 5.1 W (receiver)
Power factor4 (rack units only)
ProtectionSolid-state short circuit protection
Optional power supplyModel 615P-1/EU (Order Code: 188-3178/EU) or 615P-1/UK (Order Code: 188-3178/UK)
Environmental
Operating temperature-40 to 167°F (-40 to 75°C)
Maximum humidity95% relative,​ noncondensing
Standards
EmmissionsFCC Part 15,​ ICES-003,​ AS/NZS 3548,​ EN55022
ImmunityENV50204,​ EN61000-4-2,​ -3,​ -4,​ -5,​ -6,​ -11
SafetyUL 1950,​ CAN/CSA 22.2,​ NO. 950-95
Laser safetyEN60825
Mechanical
Dimensions (LWD), standalone units5.0 in. x 4.8 in. x 1.5 in. (127 mm x 122 mm x 38 mm)
Dimensions, rack units1 slot (1.0 in.)
WeightStandalone 1.21 lb. (0.55 kg); rack 0.7 lb. (0.32 kg)
ConstructionPolycarbonate (standalone); Aluminum (rack)
  • COME CONTATTARCI

I nostri riferimenti

  • Via Campegna 135, 80124 - Napoli
  • +39 081 5936511 - 081 2425588
  • info@sicurtecnicanapoli.it
  • LINK AL SITO
  • Privacy Policy
  • Cookie Policy
  • Contattaci
  • FAQ
  • Iscriviti alla nostra Newsletter

inserendo la tua email, accetti le nostra Privacy Policy.

Copyright 2022 - Sicurtecnica S.r.l. - P. Iva 01400990634

**Richiesta preventivo Leggi la nota nei "Servizi" come procedere per la richiesta! Ignora

[ Placeholder content for popup link ] WordPress Download Manager - Best Download Management Plugin

×

Come sostituire la batteria di Button

Per sostituire la batteria:

Separare le due metà della custodia usando un oggetto piatto sottile.

Rimuovere la batteria scarica.

Installare una nuova batteria di tipo CR2032. Il segno + sulla batteria deve corrispondere al segno + sul quadro del dispositivo.

 
 

Non installare in alcun caso batterie scariche o danneggiate.

Riassemblare Button e verificarne il corretto funzionamento premendo il pulsante.
 

Prima di eseguire la verifica, assicurarsi di notificare l’istituto di vigilanza e gli utenti connessi, e di disattivare l’attivazione della sirena nelle impostazioni di Button se non si desidera che la sirena reagisca all’allarme del pulsante.

Estensione

Durata

Precisione

Stabilità

Sicurezza

Flessibilità

Superiorità

Autonomia

Invulnerabilità

Specifiche

Durata

Creare un sistema che funziona sulle lunghe distanze è facile. Garantire che funzioni regolarmente è assai più difficile. Abbiamo dotato l’hub di una
tecnologia intelligente in grado di mantenere la potenza in uscita a un livello minimo. Ciò consente ai rilevatori di funzionare in maniera stabile fino a 7 anni.

Durata

Accedi

Become a part of our community!
Forgot your password? Get help
Privacy

Reset password

Recover your password
A password reset link will be e-mailed to you.
Privacy
Back to
Login
×

Il prodotto è stato aggiunto al carrello

0 prodotti nel carrello (€0,00)

Continua... Vai al carrello